LED floodlights for Zone 2 & 22 Series PRO-N:

PRO-N Series floodlights with LED technology combine a lightweight and compact design with high performance in terms of reliability and efficiency. The rugged housing with cooling fins provides optimal cooling for long life of the internal LED boards in an industrial environment, while an optional optical system with lenses allows the light flux to be controlled and illuminated only where needed.

The lighting fixtures can be installed in Zone 2 & 22.

Benefits and features:

  • Ex protection: II3GD Ex nR IIC T5 Gb, Ex tc IIIC T95°C Dc IP66
  • Ambient temperature: -20°C ÷ +40°C (Optional +60°C with lower temperature class)
  • Certificate: CEC 15 ATEX 045
  • Housing: Aluminum with gray epoxy coating
  • Diffuser: Impact resistant glass (4 Joule impact)
  • Swivel bracket and screws: Stainless steel AISI 304
  • Connection terminals: Terminal block 3x2.5mm²
  • Swivel inputs: 1 or 3 inputs M20x1.5, depending on type
  • Power: 25W ÷ 240W
  • Luminous flux: 3,000lm ÷ 34,000lm
  • Correlated color temperature (CCT): 4,000K ÷ 5,700K
  • Color rendering index (CRI): > 80
  • Supply voltage: 230Vac 50/60Hz ±10% or 24Vdc ±10% as standard
  • LED driver: On board LED driver as standard (On request, an external LED driver with wide voltage range is available)

Downloads

Product
Normal operation
Emergency operation
Classifictation
BTLE230RUN240(1H)
Article: BTLE230RUN240(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x35W
7200 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE230RUN240(3H)
Article: BTLE230RUN240(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x35W
7200 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE30RUN240(1H)
Article: BTLE30RUN240(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x35W
3600 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE30RUN240(3H)
Article: BTLE30RUN240(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x35W
3600 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLEE15RUN240(1H)
Article: BTLEE15RUN240(1H)
Non-maintained emergency lighting (Operation only in case of emergency)
5.500K

lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLEE15RUN240(3H)
Article: BTLEE15RUN240(3H)
Non-maintained emergency lighting (Operation only in case of emergency)
5.500K

lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
LTC05Q-230AC
Article: LTC05Q-230AC
Lighting without emergency function
5.500K
5W
450 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC05Q-24DC
Article: LTC05Q-24DC
Lighting without emergency function
5.500K
5W
500 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC05YQ-24DC
Article: LTC05YQ-24DC
Lighting without emergency function
5.500K
5W
500 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10A-24DC
Article: LTC10A-24DC
Lighting without emergency function
5.500K
9W
1000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10Q-230AC
Article: LTC10Q-230AC
Lighting without emergency function
5.500K
9W
900 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10Q-24DC
Article: LTC10Q-24DC
Lighting without emergency function
5.500K
9W
1000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10YQ-24DC
Article: LTC10YQ-24DC
Lighting without emergency function
5.500K
9W
1000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC15A-24DC
Article: LTC15A-24DC
Lighting without emergency function
5.500K
15W
1750 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC15Q-24DC
Article: LTC15Q-24DC
Lighting without emergency function
5.500K
15W
1750 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC15YQ-24DC
Article: LTC15YQ-24DC
Lighting without emergency function
5.500K
15W
1750 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC20Q-230AC
Article: LTC20Q-230AC
Lighting without emergency function
5.500K
17W
1800 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC20Q-24DC
Article: LTC20Q-24DC
Lighting without emergency function
5.500K
17W
2000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC20YQ-24DC
Article: LTC20YQ-24DC
Lighting without emergency function
5.500K
17W
2000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC30Q-230AC
Article: LTC30Q-230AC
Lighting without emergency function
5.500K
26W
2700 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db

Emergency function

Series

More series... Less series

Atex Zone

Voltage

Ambient temperature

-

Power

-

Flux

-

CCT

-
Reset filter