LED line fittings in GRP for Zone 2 & 22 Series SVN

LED line fixtures in GRP for Zone 2 & 22 Series SVN:

SVN Series LED line fixtures consist of a GRP housing with matte UV resistant polycarbonate cover. Internally, the fixtures are equipped with an LED strip and driver. The fixtures are only available in 3 types.

The lighting fixtures can be installed in zone 2 & 22.

Features:

  • Ex protection: II3GD Ex ec IIC T6 Gc, Ex tc IIIC T70°C Dc IP66
  • Ambient temperature: -25°C ÷ +40°C/+60°C  
  • Certificate: TUV CY 21 ATEX 0206415 X
  • Housing: Glass fiber reinforced polyester, white
  • Diffuser: UV resistant polycarbonate 
  • Screws & accessories: Stainless steel AISI 304
  • Connection terminals: Terminal block 3x2.5mm²
  • Gland entries: 1 or 2 M20 entries
  • Power rating: 36, 50 & 75W
  • Luminous flux: 4,000lm (36W), 7,200lm (50W) & 11,000lm (75W)
  • Supply voltage: 230Vac 50/60Hz ±10% as standard

Downloads

Product
Normal operation
Emergency operation
Classifictation
AVNL336
Article: AVNL336
Lighting without emergency function
2.800K ÷ 6.500K
Max 3x32W
7500 lm

-
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNL36
Article: AVNL36
Lighting without emergency function
2.800K ÷ 6.500K
Max 1x32W
2500 lm

-
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE18(1H)
Article: AVNLE18(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 1x16W
1250 lm
13W (1hr)
1300 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE18(3H)
Article: AVNLE18(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 1x16W
1250 lm
4W (3Hrs)
550 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE218(1H)
Article: AVNLE218(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 2x16W
2500 lm
13W (1hr)
1300 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE218(3H)
Article: AVNLE218(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 2x16W
2500 lm
4W (3Hrs)
550 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE236(1H)
Article: AVNLE236(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 2x32W
5000 lm
13W (1hr)
1300 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE236(3H)
Article: AVNLE236(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 2x32W
5000 lm
4W (3Hrs)
550 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE36(1H)
Article: AVNLE36(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 1x32W
2500 lm
13W (1hr)
1300 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE36(3H)
Article: AVNLE36(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 1x32W
2500 lm
4W (3Hrs)
550 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLEE18(1H)
Article: AVNLEE18(1H)
Non-maintained emergency lighting (Operation only in case of emergency)
2.800K ÷ 6.500K

lm
13W (1hr)
1300 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLEE18(3H)
Article: AVNLEE18(3H)
Non-maintained emergency lighting (Operation only in case of emergency)
2.800K ÷ 6.500K

lm
4W (3Hrs)
550 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
BTL15RUN240
Article: BTL15RUN240
Lighting without emergency function
5.500K
1x17W
1800 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTL215RUN240
Article: BTL215RUN240
Lighting without emergency function
5.500K
2x17W
3600 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTL230RUN240
Article: BTL230RUN240
Lighting without emergency function
5.500K
2x35W
7200 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTL30RUN240
Article: BTL30RUN240
Lighting without emergency function
5.500K
1x35W
3600 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE15RUN240(1H)
Article: BTLE15RUN240(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x17W
1800 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE15RUN240(3H)
Article: BTLE15RUN240(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x17W
1800 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE215RUN240(1H)
Article: BTLE215RUN240(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x17W
3600 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE215RUN240(3H)
Article: BTLE215RUN240(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x17W
3600 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db

Emergency function

Series

More series... Less series

Atex Zone

Voltage

Ambient temperature

-

Power

-

Flux

-

CCT

-
Reset filter