LED lighting fittings in GRP Zone 1 & 21 Series AVL

LED Tube light fixtures in GRP for Zone 1 & 21 Series AVL:

AVL Series LED tube light fixtures consist of a robust GRP housing with 2.5mm thick and impact resistant UV resistant polycarbonate cover. Internally, the fixtures are equipped with Ex mb cast LTT LED tube lamps. Up to 3 tube lamps can be installed per fixture, available in two lengths. The tube lamps can be individually rotated to spread or adjust the luminous flux. Optionally, the fixtures are available with battery for emergency situations and an external LED driver for a wide voltage range or for environments with mains contamination.

The lighting fixtures can be installed in Zone 1, 21, 2 & 22.

Features:

  • Ex protection: II2GD Ex d e mb IIC T5 Gb, Ex tb IIIC T70°C Db IP66
  • Ambient temperature: -25°C ÷ +50°C 
  • Certificate: CEC 13 ATEX 024
  • Housing: Glass fiber reinforced polyester, Black
  • Diffuser: Impact resistant UV resistant polycarbonate 
  • Screws & accessories: Stainless steel AISI 304
  • Connection terminals: Terminal block 3x2.5mm²
  • Gland entries: 1 or 2 M25 entries
  • LED Tubes: Cosime LTT Ex mb (CEC 14 ATEX 054 U)
  • Luminous flux: 900lm/W (Standard On-board driver) or 1,150lm/W (External LED Driver)
  • Correlated color temperature (CCT): 5,500K
  • Color rendering index (CRI): > 80
  • Supply voltage: 230Vac 50/60Hz ±10% as standard
  • Battery: Ni-Cad, 3.6V 
  • LED driver: On board 230V LED driver as standard (On request, an external LED driver with wide voltage range is available)

Downloads

Product
Normal operation
Emergency operation
Classifictation
AVL10
Article: AVL10
Lighting without emergency function
5.500K
1x17W
1800 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVL210
Article: AVL210
Lighting without emergency function
5.500K
2x17W
3600 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVL230
Article: AVL230
Lighting without emergency function
5.500K
2x35W
7200 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVL30
Article: AVL30
Lighting without emergency function
5.500K
1x35W
3600 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVL310
Article: AVL310
Lighting without emergency function
5.500K
3x17W
5400 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVL330
Article: AVL330
Lighting without emergency function
5.500K
3x35W
10800 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE10(1H)
Article: AVLE10(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x17W
1800 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE10(3H)
Article: AVLE10(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x17W
1800 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE210(1H)
Article: AVLE210(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x17W
3600 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE210(3H)
Article: AVLE210(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x17W
3600 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE230(1H)
Article: AVLE230(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x35W
7200 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE230(3H)
Article: AVLE230(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x35W
7200 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE30(1H)
Article: AVLE30(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x35W
3600 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE30(3H)
Article: AVLE30(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x35W
3600 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLEE10(1H)
Article: AVLEE10(1H)
Non-maintained emergency lighting (Operation only in case of emergency)
5.500K

lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLEE10(3H)
Article: AVLEE10(3H)
Non-maintained emergency lighting (Operation only in case of emergency)
5.500K

lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db

Emergency function

Series

More series... Less series

Atex Zone

Voltage

Ambient temperature

-

Power

-

Flux

-

CCT

-
Reset filter